All Stanbio Chemistry Reagents, Calibrators, Controls and Standards (A – Z)

The Stanbio Chemistry Reagents range includes liquid-stable reagents, calibrators, standards and controls that can be used on most main brand analyzers including Cobas, Architect, Dimension and Hitachi.

Stanbio Chemistry Reagents products are manufactured in our FDA regulated facility in Boerne, Texas. All stages of the Stanbio Chemistry Reagents manufacturing process are based on strict Current Good Manufacturing Practice regulations (cGMP).  We also offer OEM and contract manufacturing services.

Our LiquiColor® and Liqui-UV® Stanbio Chemistry Reagents are designed for ease of use and maximum stability.

  • Stability up to the expiration date, even after opening the bottle
  • Ready to use liquid reagent
  • Economical choice of reagent kits
  • Avoid reconstitution errors and water contamination

All Stanbio Chemistry Reagents, Calibrators, Controls and Standards (A – Z)

Product Ref no. Type Media Methodology Description of contents Linearity Read (nm)
Acetaminophen LiquiColor® test (Rate) 2400-060 Reagents Liquid Arylacylamidase/o-cresol R1: 1 x 40 mL
R2: 1 x 20 mL
STD: 1 x 3 mL
300 mg/L 615
Albumin LiquiColor®test 0285-500 Reagents Liquid Bromocresol green reaction (BCG) R: 2 x 250 mL
STD: 1 x 3 mL
7 g/dL 550
Alkaline Phosphatase
LiquiColor test (Rate)
2900-430 Reagents Liquid P-nitrophenylphosphate R1: 4 x 25 mL
R2: 1 x 20 mL
800 U/L 405
Alkaline Phosphatase
LiquiColor test (Rate)
2900-500 Reagents Liquid P-nitrophenylphosphate R1: 4 x 105 mL
R2: 4 x 20 mL
800 U/L 405
Alpha-amylase LiquiColor® test 2970-430 Reagents Liquid EPS-G7 substrate R: 4 x 30 mL 2000 U/L 405
ALT/ SGPT Liqui-UV® test
(Rate)
2930-430 Reagents Liquid IFCC recommended procedure R1: 4 x 25 mL
R2: 1 x 20 mL
600 U/L 340
ALT/ SGPT Liqui-UV® test
(Rate)
2930-500 Reagents Liquid IFCC recommended procedure R1: 4 x 105 mL
R2: 4 x 20 mL
600 U/L 340
AST/ SGOT Liqui-UV  test 2920-430 Reagents Liquid IFCC recommended procedure R1: 4 x 25 mL
R2: 1 x 20 mL
R3: 4 x 125 mL
600 U/L 340
AST/ SGOT Liqui-UV  test 2920-500 Reagents Liquid IFCC recommended procedure R1: 4 x 105 mL
R2: 4 x 20 mL
600 U/L 340
ß-Hydroxybutyrate LiquiColor® test (Endpoint) 2440-058 Reagents Liquid β-Hydroxybutyrate dehydrogenase / INT R1: 1 x 50 mL
R2: 1 x 8.5 mL
STD: 1 x 3 mL
Up to 8 mmol/L* 505
ß-Hydroxybutyrate LiquiColor® test (Beckman Synchron Cx/Lx/Dx) B2440-180 Reagents Liquid β-Hydroxybutyrate dehydrogenase / INT 2 x 90 tests Up to 8 mmol/L 520
Bilirubin Total & Direct LiquiColor® test **This kit is a combination of refs. 0245-250 and 0240-080 0260-200 Reagents Liquid Modified Walters-Gerarde R1: 1 x 100 mL
R2: 1 x 100 mL
Oxidant: 1 x 15 mL
Calibrator 1 x 6 mL
10 mg/dL (direct)
20 mg/dL (total)
540
Bilirubin Total LiquiColor® test 0240-080 Reagents Liquid Modified Walters-Gerarde R1: 1 x 250 mL
Oxidant: 1 x 15 mL
Calibrator: 1 x 6 mL (10 mg/dL)
20 mg/dL 540
Bilirubin Total LiquiColor® test
(DCa)
0230-450 Reagents Liquid DCA (2, 4-Dichloroaniline) R1: 3 x 120 mL
R2: 1 x 90 mL
0.07 – 30 mg/dL 540
Bilirubin Direct LiquiColor® Reagent 0245-250 Reagents Liquid Modified Walters-Gerarde R1: 1 x 250 mL
Oxidant: 1 x 15 mL
10 mg/dL 540
Bilirubin Direct LiquiColor® test (DCa) 0235-450 Reagents Liquid DCA (2, 4-Dichloroaniline) R1: 3 x 120 mL
R2: 1 x 90 mL
0.1 – 10 mg/dL 550
Calcium (Arsenazo) LiquiColor® test 0155-225 Reagents Liquid Arsenazo III R1: 2 x 250 mL
STD: 1 x 3 mL (10mg/dL)
15 mg/dL 650
Calcium (CPC) LiquiColor® test 0150-250 Reagents Liquid Cresolphthalein Complexone R1: 1 x 125 mL
R2: 1 x 125 mL
STD: 1 x 3 mL
(10 mg/dL)
15 mg/dL 550
Chloride LiquiColor® test 0210-250 Reagents Liquid Mercuric Thiocyanate R: 1 x 250 mL
STD: 1 x 3 mL
(100 mEq/L)
70 – 120 mEq/L 500
Cholesterol LiquiColor® test (enzymatic) 1010-225 Reagents Liquid Modified Trinder R: 2 x 250 mL
STD: 1 x 3 mL
(200 mg/dL)
750 mg/dL 500
Cholesterol LiquiColor® test (enzymatic) 1010-430 Reagents Liquid Modified Trinder R: 4 x 30 mL
STD: 1 x 3 mL
(200 mg/dL)
750 mg/dL 500
CK Liqui-UV® test
(Creatine Kinase/ UV-Rate )
2910-430 Reagents Liquid Szasz modified reaction R1: 4 x 24 mL
R2: 4 x 6 mL
1 – 1200 U/L 340
Creatinine LiquiColor® test 0430-120 Reagents Liquid Enzymatic R1: 3 x 30 mL
R2: 1 x 30 mL
30 mg/dL 550
Creatinine LiquiColor® test 0430-500 Reagents Liquid Enzymatic R1: 3 x 125 mL
R2: 1 x 125 mL
30 mg/dL 550
Creatinine LiquiColor® test
(Kinetic)
0420-500 Reagents Liquid Jaffe R1: 1 x 250 mL
R2: 1 x 250 mL
STD: 1 x 5 mL
(5 mg/dL)
20 mg/dL 510
HDL-Cholesterol test 0599-020 Reagents Liquid 1 x 20 mL
HDL-Cholesterol direct LiquiColor® test 0590-040 Reagents Liquid Homogeneous method for direct HDL measurment R1: 1 x 30 mL
R2: 1 x 10 mL
150 mg/dL 600
HDL-Cholesterol direct LiquiColor® test 0590-080 Reagents Liquid Homogeneous method for direct HDL measurment R1: 2 x 30 mL
R2: 2 x 10 mL
150 mg/dL 600
HDL-Cholesterol direct LiquiColor® test 0590-500 Reagents Liquid Homogeneous method for direct HDL measurment R1: 3 x 125 mL
R2: 1 x 125 mL
150 mg/dL 600
Cholesterol, LDL direct LiquiColor® test 0710-080 Reagents Liquid Homogeneous method for direct LDL measurment R1: 2 x 30 mL
R2: 2 x 10 mL
520 mg/dL 600
Gamma-GT LiquiColor test
(Rate)
2960-430 Reagents Liquid Modified Szasz R1: 4 x 25 mL
R2: 1 x 20 mL
300 U/L 405
Gamma-GT LiquiColor test
(Rate)
2960-500 Reagents Liquid Modified Szasz R1: 4 x 105 mL
R2: 4 x 20 mL
300 U/L 405
Glucose LiquiColor® Reagent
(enzymatic)
1071-001 Reagents Liquid Trinder R: 1 x 1000 mL 400 mg/dL 500
Glucose LiquiColor® test
(enzymatic)
1070-125 Reagents Liquid Trinder R: 1 x 250 mL
STD 1 x 3 mL
(100 mg/dL)
400 mg/dL 500
Glucose LiquiColor® test
(enzymatic)
1070-500 Reagents Liquid Trinder R: 2 x 250 mL
STD 1 x 3 mL
(100 mg/dL)
400 mg/dL 500
Glucose Liqui-UV® test
(Endpoint)
1060-500 Reagents Liquid Hexokinase R1: 4 x 105 mL
R2: 1 x 80 mL
STD: 1 x 3 mL
(100 mg/dL)
500 mg/dL 340
Glycohemoglobin direct  (HbA1c) 0360-040 Reagents Liquid Turbidimetric immunoassay R1: 1 x 30 mL
R2: 1 x 10 mL
R3 (lysing): 1 x 125 mL
2 – 16% HbA1c 600
Glycohemoglobin Pre-Fil test P350-050 Reagents Liquid Optimised Ion-exchange resin procedure 50 tests
STD: 1 x 1mL
HbA1 4 – 20%
HbA1c 2.6 – 16%
415
Glycohemoglobin test
(Hba1 and  HbA1c) test
0350-060 Reagents Liquid Optimised Ion-exchange resin procedure 60 tests
STD: 1 x 1 mL
HbA1 4 – 20%
HbA1c 2.6 – 16%
415
Iron & Total Iron Binding
Capacity test
0370-110 Reagents Liquid Ferrozine 110 tests
R: 1 x 15 mL
Buffer 1: 1 x 125 mL
Buffer 2: 1 x 125 mL
STD: 1 x 30 mL (500 mg/dL)
1000 mg/dL 560
LDH Liqui-UV® test (Rate) 2940-430 Reagents Liquid Modified wacker R1: 4 x 25 mL
R2: 1 x 20 mL
800 U/L 340
LDH Liqui-UV® test (Rate) 2940-500 Reagents Liquid Modified wacker R1: 4 x 105 mL
R2: 2 x 20 mL
800 U/L 340
Magnesium LiquiColor® test 0130-430 Reagents Liquid Xylidyl blue R:4 x 30 mL
STD: 1 x 3 mL (2 mEq/L)
4.3 mEq/L 520
Phosphorus Liqui-UV® test 0830-125 Reagents Liquid Phosphomolybdate R: 1 x 250 mL
STD: 1 x 3 mL (10 mg/dL)
20 mg/dL 340
Potassium test (Manual) 0160-050 Reagents Liquid Turbidimetric immunoassay 50 test
STD: 1 x 3 mL (4 mmol/L)
10 mmol/L 580
Salicylate Liqui-UV® test
(Endpoint)
2410-051 Reagents Liquid Salicylate hydroxylase / NADH R1: 1 x 50 mL
R2: 1 x 1 mL
STD: 1 x 3 mL (300 mg/L)
1000 mg/L 340
Sodium Test (Manual) 0140-050 Reagent Liquid Uranyl acetate 50 tests
STD: 1 x 6 mL (140 mmol/L)
160 mmol/L 420
Total Protein LiquiColor® test 0250-500 Reagents Liquid Biuret reaction R: 2 x 250 mL
STD: 1 x 3 mL (10 g/dL)
10 g/dL 550
Total Protein LiquiColor® test (CSF/ Urine) 0345-212 Reagents Liquid Pyrogallol red / Colorimetric R: 1 x 250 mL
STD: 1 x 3 mL (100 mg/dL)
150 mg/dL 600
Triglyceride LiquiColor® test
(mono)
2200-225 Reagents Liquid Glycerylphosphate oxidase (GPO) 2 x 250 mL
STD: 1 x 2 mL (200 mg/dL)
1000 mg/dL 500
Triglyceride LiquiColor® test
(mono)
2200-430 Reagents Liquid Glycerylphosphate oxidase (GPO) R: 4 x 30 mL
STD: 1 x 6 mL (140 mmol/L)
1000 mg/dL 500
Triglyeride LiquiColor® Reagent Set (enzymatic) 2100-225 Reagents Liquid Glycerylphosphate oxidase (GPO) R1: 2 x 250 mL
R2: 1 x 5.2 mL
STD: 1 x  2 mL (200 mg/dL)
1000 mg/dL 500
Triglyeride LiquiColor® Reagent Set (enzymatic) 2100-430 Reagents Liquid Glycerylphosphate oxidase (GPO) R1: 4 x 30 mL
R2: 1 x 1.8 mL
STD: 1 x 2 mL (200 mg/dL)
1000 mg/dL 500
Urea Nitrogen Liqui-UV® test
(Rate)
2020-430 Reagents Liquid Modified urease R1: 4 x 25 mL
R2: 1 x 20 mL
STD: 1 x 3 mL (30 mg/dL)
140 mg/dL 340
Urea Nitrogen Liqui-UV® test
(Rate)
2020-500 Reagents Liquid Modified urease R1: 4 x 105 mL
R2: 4 x 20 mL
STD: 1 x 3 mL (30 mg/dL)
140 mg/dL 340
Urea Nitrogen test 0580-250 Reagents Liquid Diacetylmonoxime 250 tests
STD 1: 1 x 3 mL (25 mg/dL)
STD 2: 1 x 3 mL (50 mg/dL)
STD3: 1 x 3 mL (75 mg/dL)
980 mg/dL 520
Uric acid LiquiColor® test
(enzymatic)
1045-225 Reagents Liquid Trinder 2 x 250 mL
STD: 1 x 3 mL (8 mg/dL)
20 mg/dL 520
Uric acid LiquiColor® test
(enzymatic)
1045-430 Reagents Liquid Trinder R: 4 x 30 mL
STD: 1 x 3 mL (8 mg/dL)
20 mg/dL 520
Cholesterol, Direct (HDL/ LDL) Calibrator 0595-003 Calibrators Powder Lyophilized human serum containing HDL and LDL 1 x 3 mL
Glycohemoglobin direct (HbA1c) Calibrators 0365-401 Calibrators Powder Requires reconstitution 4 x 0.5 mL
Ser-T-Cal Multi-Calibrator 0550-605 Calibrators Powder Lyophilized, requires reconstitution 6 x 5 mL
Glycohemoglobin (HbA1c) direct controls set 0355-201 Controls Powder Purified lipid hemolysate, requires reconstitution 2 x 0.5 mL
Glycohemoglobin bi-level controls 0357-201 Controls Powder Purified blood hemolysate, requires reconstitution 2 x 1 mL
Ser-T-Fy® Level 1 Control assayed serum G427-86 Controls Powder Lyophilized, requires reconstitution 6 x 5 mL
Ser-T-Fy® Level 2 Control assayed serum G428-86 Controls Powder Lyophilized, requires reconstitution 6 x 5 mL
ß-Hydroxybutyrate / TDM bi-level controls 2465-605 Controls Liquid Ready to use 6 x 5 mL (3 low, 3 high level)
ß-Hydroxybutyrate / TDM tri-level controls 2460-605 Controls Liquid Ready to use 6 x 5 mL (2 low, 2 medium, 2 high level)
Cholesterol Standard (200 mg/dL) 1012-030 Standards Liquid 1 x 30 mL
Glucose Standard (100 mg/dL) 1072-030 Standards Liquid 1 x 30 mL
ß-Hydroxybutyrate / TDM Linearity Standards 2450-604 Standards Liquid Liquid-ready-to-use 6 x 4 mL

*Application dependent