Biosen R-Line lactate and glucose analyzer

Dual channel lactate and glucose measurements for research lab use
Easy measurements in 3 steps

1. Collect sample into capillary tube.

2. Place capillary into cup and invert until mixed.

3. Result in 20–45 seconds.
Easy to use
- Multi-lingual touch screen display with step by step instructions
- Only 20 μl of sample required when used with our pre filled ‘Safe-Lock’ reaction cups (1000 μl)
- Up to 120 results per hour
- Results in 20-45 seconds
- Automatically detects presence of reaction cups
- Chip sensors easily exchangeable, no electrode cleaning required
Accurate and reliable
- Enzymatic-amperometric method using chip-sensor technology
- Measuring range: Glucose 0.5–50 mmol/L (9–900 mg/dL); Lactate 0.5–40 mmol/L (5–360 mg/dL)
- Imprecision: CV ≤1.5 % (12 mmol/L)
- Pre-filled ‘Safe-Lock’ reaction cups eliminate manual dilution
- Innovative needle and exchanger design eliminates cross contamination
- 3 calibration modes
Maximum efficiency and convenience
- Dual channel allows for glucose and/or lactate results from one sample
- Long sensor life: Glucose 60 days/7,500 tests; Lactate 50 days/6,000 tests
- Sample stable for up to 5 days (refrigeration recommended)
- STAT position for immediate results
Efficient data handling
- PC, network and printer connectivity via RS232C interfaces
- Stores up to 1,000 results
- Integrated barcode reader
Key Features
Specifications
- Principle: Enzymatic-amperometric
- Sample Type: various including venous, arterial and capillary blood, plasma, serum, fermentation broth, cell culture media
- Sample Size: 20 µl
- Measuring Range: Glucose 0.5–50 mmol/L (9–900 mg/dL); Lactate 0.5–40 mmol/L (5–360 mg/dL)
- Imprecision: CV ≤1.5 % at 12 mmol/L
Product Support Documents
Ordering Information
Description | Reference Number | Pack Qty |
---|---|---|
Biosen R-Line | 5290-0011 | 1 pc. |
Description | Reference Number | Pack Qty |
---|---|---|
RUO Chip Sensor Glucose | 6130-3012 | 1 pc. |
RUO Chip Sensor Lactate | 6130-3022 | 1 pc. |
RUO Dummy Sensor | 6130-3032 | 1 pc. |
RUO Glucose/Lactate hemolyzing solution with 20 µL end-to-end plastic capillaries (Sodium [Na+] heparinized, |
6130-3113 | Set of 1000 |
RUO Glucose/Lactate hemolyzing solution with 20 µL end-to-end plastic capillaries (Sodium [Na+] heparinized, |
6130-3114 | Set of 200 |
RUO Sensor test solution for glucose and lactate, ready for use | 6130-6126 | 20 pcs. |
RUO Cleaning solution and protein remover, concentrated | 6130-6217 | 5 pcs. |
RUO Disinfectant solution, concentrated | 6130-6227 | 5 pcs. |
Description | Reference Number | Pack Qty |
---|---|---|
RUO Glucose/Lactate System Solution | 6130-3214 | 2,500 mL |
RUO Multi standard solution 12 mmol/L, ready for use | 6130-3221 | 50 pcs. |
RUO ReadyCon Norm, test solution for glucose and lactate, ready for use | 6130-6015 | 25 pcs. |
RUO ReadyCon Pat, test solution for glucose and lactate, ready for use | 6130-6025 | 25 pcs. |
RUO Linearity test kit glucose/lactate, 2-7-18 mmol/L | 6130-6116 | 3×3 pcs. |